Search Authority

BD Alaris Infusion Set 116: Low Sorbing Tubing & SmartSite Filter

The bd alaris infusion set 116 low sorbing tubing filter smartsite is designed for sensitive medication delivery, minimizing extracted contaminants and improving dose accuracy....

Mara Ellison
BD Alaris Infusion Set 116: Low Sorbing Tubing & SmartSite Filter

The bd alaris infusion set 116 low sorbing tubing filter smartsite is designed for sensitive medication delivery, minimizing extracted contaminants and improving dose accuracy. This system combines low sorbing tubing with a precision smartsite interface to support consistent flow during critical infusions.

Engineered for compatibility with a wide range of medications, this set targets clinicians who require reliable priming volumes and reduced risk of dose deviation. The integrated smartsite provides a secure, sharps-free connection that supports safe handling and accurate flow control in complex care environments.

Key Feature Specification Clinical Relevance Compatibility Notes
Tubing Type Low sorbing polypropylene Reduces adsorption of protein-based and lipid medications Suitable for amino acids, lipids, and narrow therapeutic index drugs
Filter Integration Integrated microfilter in tubing path Removes particulate matter while maintaining laminar flow Compatible with standard ancillary filters when clinically indicated
Priming Volume Approximately 1.2 mL Low priming supports smaller peripheral lines Reduces dilution for neonates and pediatric patients
Connector System SmartSite closed access connector Needle-free access with push-pull activation
  • Lower contamination risk and ease of use in multi-dose workflows
  • Low Sorbing Tubing Design for Medication Integrity

    Low sorbing tubing minimizes the adsorption of medications to the plastic surface, which is critical for maintaining accurate dosing of potent drugs. In the bd alaris 116 set, this design supports stable concentrations of protein-based therapies and lipid emulsions throughout the infusion.

    By reducing the interaction between the drug and the tubing wall, clinicians can rely more confidently on the labeled dose reaching the patient. This is especially important in settings where narrow therapeutic index medications are administered through small bore peripheral catheters.

    SmartSite Closed Access Connector for Safer Use

    The smartsite connector on the bd alaris 116 set provides a needle-free interface that enhances safety during routine drug administration. Its push-pull activation allows for rapid connection changes while maintaining a secure seal that limits exposure to blood and medication residues.

    This design also supports compatibility with standard luer devices, enabling clinicians to use familiar accessories without compromising the closed-system integrity. The connector's low dial resistance facilitates smoother priming and reduces hand fatigue during high-volume workflows.

    Pediatric and Neonatal Dosing Advantages

    In neonatal and pediatric care, minimizing priming volume and sorbing surfaces helps preserve limited drug quantities and reduces the risk of underdose. The low sorbing tubing in this set limits drug loss, which is essential when administering expensive or limited-supply medications.

    The compact design and lower tubing compliance allow for more predictable delivery of small volumes, supporting precise control during titratable infusions common in pediatric intensive care units.

    Integration with Existing Alaris Pump Platforms

    The bd alaris infusion set 116 is designed to interface seamlessly with the alaris pump platform, ensuring proper electronic communication for dose tracking and safety checks. This integration reduces setup errors and supports consistency across medication libraries.

    Clinicians benefit from automated compatibility alerts and the ability to store drug-specific profiles, enhancing workflow efficiency and reducing the likelihood of administration errors in fast-paced environments.

    Clinical Recommendations and Key Takeaways

    • Use the bd alaris infusion set 116 for medications prone to adsorption or when precise low-volume dosing is required
    • Verify compatibility with the specific medication and ancillary filter requirements before administration
    • Leverage smartsite connector advantages for safer handling and reduced need for needle recapping
    • Integrate with alaris pump platform features to access automated safety checks and documentation
    • Review facility protocols for pediatric and neonatal dosing to align priming volume and flow control strategies

    FAQ

    Reader questions

    Does the low sorbing tubing reduce the need for secondary filters in routine drug administration?

    The integrated microfilter addresses particulate removal during infusion, but secondary filters are still recommended based on line integrity, patient-specific factors, and facility policy for high-risk medications.

    Can this set be used with vasoactive medications that require continuous precise dosing?

    Yes, the low sorbing tubing and smartsite connector support stable delivery of vasoactive agents, helping to maintain consistent plasma levels during critical care infusions.

    Is the bd alaris infusion set 116 compatible with all standard IV administration sets and pumps?

    It is specifically optimized for alaris pump platforms and standardized IV administration sets; using non-approved components may affect dose accuracy, electronic communication, and safety functionality.

    How does the tubing sorbing level impact drug stability during extended infusions?

    Lower sorbing characteristics reduce drug adsorption to the tubing wall, which helps preserve medication potency and predictable pharmacodynamics during prolonged infusions of sensitive agents.

    Related Reading

    More pages in this topic cluster.

    Brigand (Fire Emblem):角色 profile 与战斗指南

    在 Fire Emblem 系列中,Brigand 是一种以近战物理为特色的敌我通用职业,通常使用刀剑或斧头,偏向高机动与中等攻击的组合。相较于 Sw...

    Read next
    Cleo in King's Raid:角色背景、定位与养成指南

    Cleo 是 King's Raid 中以机动性与持续输出见长的角色,主要承担副输出或功能型前锋职责。她在队伍中的核心价值体现在灵活切入战场、...

    Read next
    Oldest Ice Skater: Defying Age on the Ice

    The title of oldest ice skater often refers to dieners who have competed or performed well into their eighties and nineties. These athletes combine decades of training with bala...

    Read next